USB
GPI 8/8 for Windows 2000 and XP
| This USB device is an update physical unit to the older USB-8 described here. Please verify that the unit is an USB 8/8 device before installing. |
|
|
NOTE: Support for these units was added in DAD 5.1.D (Sep.06) |
1.
Install the
Instacal Software that was provided with the card. If the software is not
available, it can be downloaded at: http://www.computerboards.com/download.htm
|
|
NOTE: This MUST happen before DAD will see the USB device. |
Modify this line to: REMOTE=UNIVERSAL
NOTE: The line GPO_GPI=0 0 0 should be left as is. DAD will automatically fill in these values depending on the type / style of the GPI Device.
To test the card, start DAD, open the LIBRARY, open the COMMAND window and type the line PULSE GPO 1 1000 and hit EXECUTE. This will send a relay from DAD to GPO 1. One should be able to hear a “click” on the unit itself when the relay opens, then closes.
|
|
Other notes: If a different unit has been plugged into a pre-configured DAD workstation, the application will say there is a unit on 0 and 1. One should delete the unit on 0 (select the unit and press the big red X). After doing this reboot the workstation. When the workstation reboots, go back into the application and Test a relay. Now DAD will talk to the new unit. | ![]() |